ATLANTIC TYPHOON AIR PUMP OPERATION MANUAL:

 
Atlantic typhoon air pumps manual

Includes Models: TA1800 - TA3600

 

Atlantic Typhoon Air Pumps Operation Manual - Printable PDF Version

 

Introduction

Thank you for selecting Atlantic’s Typhoon TA1800/TA3600 Air Pump. Before using this air pump please take a moment to review this manual.

This pump is designed to pump air. The oil-free, double damping air pump system produces a large volume of air at high pressure and low noise. The aluminum casing and outer housing cover dissipate heat quickly and shield the compressor from the elements in an outdoor application.

Atlantic’s Typhoon Air Pump may be used in a variety of water related applications including oxygenation of ponds and aquariums and de-icing of outdoor ponds.

To avoid an accident, do not use the pump in any way other than as described in this manual. Please note the manufacturer cannot be responsible for accidents arising because the product was not used as prescribed. After reading this manual keep it as a reference in case questions arise during use.

Atlantic Typhoon air pump Figure 1

Prior to Operation and Installation

When the pump is delivered, first perform the following checks:

  • Check for any damage to pump and power cable that may have occurred during shipping.
  • Check the model number to make sure it is the product that was ordered and verify the voltage and frequency are correct.

Caution

  • DO NOT operate this product under any condition other than those for which it is specified. Failure to observe this precaution can lead to electrical shock, electrical leakage, fire, water leakage or other problems.
  • Please only use with a power supply voltage within 110-120 volt 60 Hz.
  • Always turn off power or unplug the pump prior to performing any maintenance or placing your hands into the water.

CAUTION:
THIS AIR PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER.

WARNING:
RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING TYPE RECEPTACLE.

Electrical Safety

  • Electrical wiring should be installed by a qualified electrician in accordance with all applicable safety regulations. Incorrect wiring can lead to pump malfunction, electrical shock or fire.
  • Air Pumps must be protected by a ground fault circuit interrupter (GFCI).
  • Air Pumps must be plugged into a standard, properly grounded, three pronged outlet.

Safety Instructions

Atlantic Typhoon air pump Figure 2

  • If the pump falls into the water, do not reach for it. First unplug the air pump or disconnect the power supply and then retrieve the pump. Let a qualified technician inspect the pump if immersion occurs.
  • Do not lift, lower or handle the pump by pulling on the electrical cord. Make sure the electrical cable does not become excessively bent or twisted and does not rub against a structure in a way that might damage it.
  • The submersible pump should not be used if the electrical supply cable is damaged in any way. If a cable with damaged insulation is submerged in water, there is danger of water seeping into the pump motor and causing a short. Altering the electrical cable in any way will void the warranty.

Installation

Pump Placement:
The following factors must be considered when choosing a location for the air pump.

  • Typhoon Air Pumps feature weather-proof aluminum housings for outdoor use. However, installation in a dry, well-ventilated area will further prolong the service life of the air pump.
  • Typhoon Air Pumps must be placed on a flat, stable surface above the water level of the pond.
  • Proper ventilation is critical for heat dissipation and operation. Never cover the air pump unless adequate airflow to the pump is provided.
  • Tubing must always be run on a downward slope away from the air pump to avoid condensation damage.

Air Pump Connections
Typhoon Air pumps will accept multiple sizes of tubing. Please refer to the chart on page 2 for acceptable tubing diameters for this model of Air Pump. Using large diameter tubing and avoiding sharp bends will improve performance of this air pump after installation.

  • Multiple air stones can be connected to the pump outlet by adding a 2-way air splitter.

Use new and sufficiently large air stones with enough discharge capacity. Air stones that are too small, old, worn out or placed too deep will reduce the output capacity. Place air stones no deeper than 7’ (TA1800) and 11’ (TA3600) below the surface of the water. Avoid kinks and tight turns in the tubing run and take care to never fully close off the pump outlet. Ensure that the pump can discharge sufficient air at all times, otherwise the pump will overheat leading to diaphragm and compressor failure. Please note that an ambient temperature above 110° F can cause the diaphragm to overheat and crack.

To prevent any water from flowing back into the pump when powered off, it is advisable to install the pump above water level. Tubing must run at a downward slope away from the compressor. The use of an inline check valve is also recommended to further prevent moisture damage.

Service & Maintenance

Dust and debris blocking the air intake may cause abnormal noises or result in a failure of the pump. Periodic cleaning of the air intake and sponge is recommended:

  • Unplug the air pump before cleaning or replacing the air intake sponge.
  • Remove the air intake cover, intake filter and clean with mild detergent.
  • Rinse the components thoroughly and allow to dry completely before reinstalling.

Atlantic Typhoon air pump Figure 3

Diaphragm replacement
Rubber diaphragms are a wearable part that will need servicing over time. Moisture, heat and dust will all shorten the life of the diaphragms. Please follow the following steps when installing replacement diaphragms.

  • Remove the top cover housing for the air pump. Loosen the air chamber screws (1) and remove the outer air chamber (2).
  • Loosen the diaphragm nut (3) and remove the diaphragm depressor (4), electrostatic membrane (5) and the damaged diaphragm (6).
  • Install the new diaphragm ensuring that the rubber tabs align properly with the notches on the inner air chamber.
  • Once the diaphragm is seated properly, assemble the components by following the previous steps in reverse order.

Atlantic Typhoon air pump Figure 4

Warranty

All Typhoon Air Pumps carry a one year limited warranty. This limited warranty is extended solely to the original purchaser commencing from the date of original purchase receipt. The following apply:

  • Manufacturer will replace parts found to be defective including pump body, housing, electric cord, swing arm and internal moving parts.
  • Air filter, flapper valves and diaphragms are wearable parts and not covered by this warranty.
  • A cut or altered power cord voids this warranty.
  • A misused or abused air pump voids this warranty.

Warranty Claims

In case of warranty claims, the air pump should be returned to place of purchase accompanied by original receipt.

Atlantic Typhoon air pump Figure 5

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this precaution can result in a serious accident.

Before ordering repairs, carefully read through this instruction booklet. If the problem per- sists, contact your dealer.

Problem Possible Cause Possible Solution
Air pump does not start Power is off
Power failure
Voltage drop/ Overload
Power cord is not connected
Turn power on
Check power supply or contact local power company
Check/Replace the GFI (Ground Fault Interrupter)
Connect power cord
Air pump stops after starting Air pump is overheating
Power/Current overload
Allow pump to cool
Check length/size of power cable. Check or replace GFI
Diminished air flow rate or no air flow Kink/damaged tubing
Dirty filter media
Worn/damaged diaphragm
Air line is submerged below operating depth
Repair/replace tubing
Clean filter media
Consult your dealer. Replace diaphragm and flappers
Raise air line to desired depth